The Nikon Super Coolscan 4000 ED film scanner is the professionals' choice for high-resolution, high-performance scanning. Featuring an LED light source and Scanner Nikkor ED glass lens, this scanner provides incredible, consistent color and sharpness. The Super Coolscan 4000 ED also integrates Digital ICE 3 Image Enhancement software for automatic removal of surface defects, restoration of color, and grain removal from scans of 35mm strip or slide film, uncut 35mm roll film and Advanced Photo System (IX240) film - NEW! 4,000 dpi Optical Resolution with fast 38 second scan times
- NEW! IEEE 1394 Interface (interface card included for Mac® OS or Windows®)
- Scanner Nikkor ED high-resolution lens, using Nikons extra-low dispersion glass for sharp, clear images
- Nikon's Color Management System ensures vivid, accurate color matching on monitors, printers and the web
- Dynamic range of 4.2 provides incredible detail throughout a wide range of tones
- LED light source for accurate color consistency without having to calibrate/replace the light source
- High-quality 48-bit images at file sizes up to 130 MB
- NEW! Applied Science Fiction's Digital ICE³ (TM) Image Enhancement Technology incorporating Digital ICE(TM), Digital ROC(TM) and Digital GEM(TM)
- NEW! Enhanced Nikon Scan® software for easier operation
- Multi-Sample Scanning, enhanced for greater flexibility
- NEW! Roll Film adapter for scanning an uncut roll of 35mm film, up to 40 frames (Optional accessory)
- Auto Slide Feeder for unattended batch scanning of up to 50 slides (Optional accessory)
 Due to a change in the manufacturers policy, in the event that this Nikon product is defective, it must be sent directly to any one of Nikon's numerous nationwide facilities for repair or replacement under warranty. |
| Film Type: |
35mm/Advanced Photo System Film (IX240) (Advanced Photo System adapter optional), Slide glass for microscope (with optional adapter) (positive, negative, color, or monochrome) |
| Reading Resolution: |
3,946-pixel monochrome linear
CCD; 4,000 dpi optical resolution |
| Film Adapter: |
Slide Mount Adapter MA-20(S); Strip Film Adapter SA-21 (2 to 6 frames); Strip Film Holder FH-3 (1 to 6 frames); IX240 Film Adapter IA-20(S) (15,25,40 frames, optional); Roll Film Adapter SA-30 (2 to 40 frames, optional); Slide Feeder SF-200(S) (1 to 50 frames, optional); Medical Slide Holder FH-G1 (for slide glass, optional) |
| Scanning Area: |
25.1 x 38mm (3,946 x 5,959 pixels) |
| Effective Scanning Area: |
SA-21: 23.3 x 36.0mm (3,654 x 5,646 pixels) |
| Effective Scanning Area: |
MA-20(S): 25.1 x 36.8mm* (3,946 x 5,782 pixels) *Actual effective size depends on slide mount aperture size |
| Effective Scanning Area: |
FH-3: 24.0 x 36.0mm (3,762 x 5,646 pixels) |
| Effective Scanning Area: |
IA-20(S): 16.1 x 26.9mm (2,525 x 4,219 pixels) |
| Effective Scanning Area: |
SA-30: 23.3 x 36.0mm (3,654 x 5,646 pixels) |
| Effective Scanning Area: |
SF-200(S): 25.1 x 36.8mm* (3,946 x 5,782 pixels) *Actual effective size depends on slide mount aperture size |
| Effective Scanning Area: |
FH-G1: 22.9 x 35.0mm (3,591 x 5,488 pixels) |
| Illumination Method: |
R, G, B and D-LED Array |
| Color Separation: |
RGB line sequential |
| Imaging Optics: |
Scanner Nikkor ED glass lens (7 elements in 4 groups including 3 ED glass elements) |
| Focusing: |
Autofocus and Manual Focus |
| Scan Time: |
Approx 38 seconds at 4,000 dpi (35mm), 16-bit output (typical scan time with display, Windows®, CMS off) |
| Optical Density: |
4.2 dynamic range |
| Thumbnail Scanning and Batch Scanning: |
35mm (135) strip film; 2 to 6 frames; IX240 film cartridge: 15,25,40 frames (with optional adapter); 35mm (135) strip film (with SA-30): 2 to 40 frames; 35mm (135) mount film (with SF-200(S)): 1 to 50 frames |
| A/D Conversion: |
14-bits |
| Output data: 16-bits, 8-bits per color channel (user selectable) |
| Digital ICE: |
Digital
ICE(TM) - automatic removal of surface defects |
| |
Digital
ROC(TM) - automatic restoration of lost color values and exposure
correction |
| |
Digital
GEM(TM) -automatic minimization of film grain in scanned images |
| Multi-sample scanning: |
2, 4, 8, 16 times (user selectable) for reduced noise |
| Color Management System: |
Built in; uses standard ICC profiles to color match across input devices. Apple ColorSync® and Microsoft® ICM compatible |
| Panel Indicators: |
READY, BUSY and ERROR status indicated by front LED |
| Scanning Software: |
Nikon Scan® 3.0 |
| Interface: |
IEEE 1394
(OHCI Compliant) |
| Operating Systems: |
Mac®OS 8.6 or later, Windows®98 Second Edition, Windows® Me, and Windows® 2000 |
| Power Requirements: |
100-240
VAC, 0.3-0.2A, 50/60Hz |
| Environmental: Temperature: |
50-95° F (10-35° C); Relative Humidity: 20-60% (non-condensing) |
| Dimensions
(W x H x D): |
3.7 x 6.6 x 12.4 in. (93 x 169 x 315mm) |
| Weight (approx.): |
6.6 lbs (3kg) |
| Includes: |
IEEE 1394 cable (6 pin, 6 pin), IEEE 1394 Interface card (works with Windows® & Macintosh® G3 or later computers), Canto
Cumulus(TM) 5.0 Demo, Nikon Scan® 3.0 Driver software, Slide Mount Adapter MA-20(S), Strip Film Adapter SA-21, Strip Film Holder FH-3, AC Power cord, software manual, and user manual.
|
|
|