- Plus network-grade AC surge suppression
- 500VA/300 watt power handling capability compatible with networking, telecom and other sensitive electronic devices
- Supports 1U rackmount installation in 2 or 4 post rack enclosures, upright tower placement also supported - mounting accessories included
- Large internal batteries offer runtimes of 17 minutes at half load (250VA/150 watts) and 5 minutes at full load (500VA/300 watts)
- Maintains regulated 120V nominal output during brownouts as low as 90V
- Includes 6 UPS-supported outlets, with one pair of individually controllable outlets that can be powered off and back on again via software
- interface
- PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, pager & email notification,
- event logging and running user-defined script commands
- Offers simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP* interfaces (*requires optional
- SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software. Free
- PowerAlert enterprise management software is also available for select opportunities
- Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage, DC
- battery voltage and remaining battery capacity
- Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for scheduled or immediate reboot
- of connected devices
- Supports Tripp Lite's WatchDog software application to restore unresponsive programs by systematically restarting applications, operating
- systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again (requires optional
- WATCHDOGSW)
- Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter
- Emergency Power Off (EPO) interface with cable
- Multi-function audible alarms and set of 5 front panel LEDs
- Network-grade AC surge suppression
- Attractive all-black color scheme
|
| Voltage compatibility | 120 VAC | | Frequency | | | compatibility | 60 Hz | | Output | | | Output VA | 500 | | Output watts | 300 | | Output nominal voltage | 120V AC | | Output voltage regulation | LINE MODE: Sine wave line voltage 120V (-15% +13%), BATTERY MODE: PWM sine wave output within 10% of 120V | | Output frequency regulation | LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-1Hz | | Outlet quantity / type | 7 NEMA 5-15R | | Customized load management receptacles | Includes single-outlet load bank that supports load shedding and remote reboot on demand of locked network devices. Controllable via PowerAlert software to switch off optional loads, like monitors, to increase available runtime for servers and other critical devices. | | Overload protection | Via 15A input breaker | | Input | | | Maximum input amps | 5.6A | | Input connection type | NEMA 5-15P | | Input cord length | 10 ft., 14 gauge, Black | | Recommended electrical service | 15A 120V | | Battery | | | Full load runtime | 3 minutes (500VA) | | Half load runtime | 8 minutes (250VA) | | DC system voltage | 12 VDC | | Battery recharge rate | 2-4 hours to 90% | | Replacement Battery Cartridge | RBC62-1U | | Voltage regulation | | | Voltage regulation description | Line interactive voltage regulation system corrects brownouts as low as 90 volts back to usable 120V nominal levels | | Brownout correction | Input voltages between 90 and 108 are boosted by 14% | | Leds alarms & switches | | | Front panel LEDs | 5 front panel LEDs - green POWER LED, green AVR LED, 3-color BATTERY CHARGE LED, 3-color OUTPUT LOAD LEVEL LED, red BATTERY WARNING LED. | | Alarms | Audible alarm warns of power failure, overload, UPS fault and low battery conditions | | Switches | Includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions | | Surge / noise suppression | | | AC surge suppression | 480 joules | | AC suppression response time | Instantaneous | | EMI / RFI AC noise suppression | Yes | | Unit Dimensions (HWD/in) | 1.75 x 17.5 x 11.75 | | Unit Dimensions (HWD/cm) | 4.45 x 44.5 x 29.8 | | Material of construction | Steel | | Form factors supported | Rack (1U) | | Battery Access | Battery access door allows hot swap battery replacement without powering connected equipment off | | Environmental | | | Operating Temperature | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius | | Storage Temperature | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius | | Relative Humidity | 0 to 95%, non-condensing | | Line mode BTU/hr. (Max.) | 65.1 | | Battery mode BTU/hr. (Max.) | 437.1 | | Communications | | | Network monitoring port | Includes 2 built-in monitoring ports, 1-USB & 1-DB9. Each supports on battery, low battery, power restored, AC line voltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperature and line frequency status | | Software and cabling included | Includes PowerAlert UPS monitoring software for network and standalone operating systems. Ships with complete USB and DB9 cabling. | | SNMP compatibility | Built-in accessory slot accommodates internal SNMP / Web card and other network accessories | | WatchDog compatibility | Yes, compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | | Line / battery transfer | | | Transfer time from line power to battery mode | 2-4 milliseconds | | Low voltage transfer to battery power | 90V (resets to line power as line voltage increases to 94V or higher) | | High voltage transfer to battery power | 136V (resets to line power as line voltage decreases to 132 or lower) | | EPO port | Includes RJ11 EPO (emergency power off) port and cable | | TVSS grounding | Includes back panel grounding point with thumbscrew for data line surge suppressors and other network accessories requiring a safe grounding point | | Cold Start | Yes, inverter can be "cold started" to enable temporary AC output during a power failure | | Appearance | Attractive all-black color scheme | |
|