- Audible alarms
- Automatic restart of loads after UPS shutdown
- Automatic self-test
- Battery replacement without tools
- Battery-protected and surge-only outlets
- Dataline surge protection
- Hot-swappable batteries
- LED status indicators
- Lifetime data recovery warranty
- Power conditioning
- Resettable circuit breakers
- Safety-agency approved
- Serial connectivity
- Transformer-block spaced outlets
- USB connectivity
- User-replaceable batteries
|
| Backup/Run Time | 5.7 Minute 300W Full-load | | | 12.1 Minute 150W Half-load | | Plug/Connector Type | NEMA 5-15P | | Receptacles | 3 x NEMA 5-15R | | Battery Recharge Time | 8 Hour Typical | | Load Capacity | 500VA | | Interfaces/Ports | 1 x DB-9 Serial | | | 1 x USB | | Certifications & Standards | FCC Part 15 Class B | | | Industry Canada | | | UL 1778 | | | cUL Listed | | Status Indicators | LED status display with On Line, On Battery, Replace Battery, Site wiring fault and Overload Indicators | | Altitude | 0 ft to 10000 ft Operating | | | 0 ft to 50000 ft Non-operating | | Alarm | On Battery | | | Low Battery | | | Overload | | Color | Beige | | Dataline Protection | RJ-11 Modem/Fax/DSL | | Filtering | Full time multi-pole noise filtering, 5% IEEE surge let-through, Zero clamping response time, Meets UL 1449 | | Humidity | 0 to 95% Operating | | | 0 to 95% Non-condensing Non-operating | | Power Cord/Cable | 6 ft | | Power Consumption | 300W Operating | | Product Line | Back-UPS | | Sound Emission | 45 dB(A) | | Surge Energy Rating | 480J | | Temperature | 32 F (0 C) to 104 F (40 C) Operating | | | 5 F (-15 C) to 113 F (45 C) Non-operating | | Thermal Dissipation | 24 BTU/h | | Waveform Type | Step Wave | | Output | | | Output Power Capacity | 300 Watts / 500 VA | | Max Configurable Power | 300 Watts / 500 VA | | Nominal Output Voltage | 120V | | Output Connections | (3) NEMA 5-15R (Battery Backup) | | | (3) NEMA 5-15R (Surge Protection) | | Input | | | Nominal Input Voltage | 120V | | Input Frequency | 50/60 Hz +/- 3 Hz (auto sensing) | | Input Connections | NEMA 5-15P | | Cord Length | 1.83 meters | | Input voltage range for main operations | 98 - 140V | | Battery Type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof | | Replacement Battery | RBC2, RBC2J | | RBC Quantity | 1 | | Typical Backup Time at Half Load | 15.4 minutes (150 Watts) | | Typical Backup Time at Full Load | 3.4 minutes (300 Watts) | | Runtime Chart | Back-UPS CS | | Interface Port(s) | DB-9 RS-232,USB | | Control panel | LED status display with On Line : On Battery : Replace Battery and Overload indicators | | Audible Alarm | Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm | | Surge energy rating | 480 Joules | | Filtering | Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 | | Dataline protection | RJ-11 Modem/Fax/DSL protection (two wire single line) | | Physical | | | Maximum Height | 165.00 mm | | Maximum Width | 91.00 mm | | Maximum Depth | 284.00 mm | | Master Carton Units | 2 | | Color | Beige | | Units per Pallet | 80 | | Operating Environment | 0 - 40 degree C | | Operating Relative Humidity | 0 - 95% | | Operating Elevation | 0-3000 meters | | Storage Temperature | -15 - 45 degree C | | Storage Relative Humidity | 0 - 95% | | Storage Elevation | 0-15000 meters | | Audible noise at 1 meter from surface of unit | 45.00 dBA | | Online Thermal Dissipation | 24.00 BTU/hr | |
|